DETAILS
Features
- Optimized for burn-through spot welding
- Deep penetration
- Little slag interference in arc
Typical Applications
- Spot Welding
- Decking to beams
- Steel with moderate surface contaminants
Welding Positions
- Flat/Horizontal
Shielding Gas
- Not Applicable
Service Information
Documentation
You May Also Need
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
CONFORMANCE
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.1 | E6022 |
MECHANICAL PROPERTIES
Classification |
Transverse Tensile Strength
MPa (ksi) |
Longitudinal Face Bend |
---|---|---|
E6022 Requirement | 410 (60) min. | No opening in excess of 1/8 inch |
Typical Result, As-welded | 450-540 (65-78) | Pass |
TYPICAL OPERATING PROCEDURES
Diameter | Polarity⁽¹⁾ |
Current
Amps |
---|---|---|
1/8 in (3.2 mm) | DC- | 110-150 |
1/8 in (3.2 mm) | AC | 110-150 |
5/32 in (4.0 mm) | DC- | 150-180 |
5/32 in (4.0 mm) | AC | 150-180 |
NOTES
Note |
---|
⁽¹⁾ Preferred polarity is listed first. |