DETAILS
SuperGlaze® 5183 PLUS
Experience the next generation of aluminum welding
SuperGlaze® 5183 Plus is Lincoln Electric's proprietary enhanced spool solution. Improved cleanliness, better operator control, and world class feeding by reduced shavings over other 5183 spool products. SuperGlaze® 5183 Plus is used over 5356 where higher strengths and improved corrosion resistance is required.+ Cosmetic Welds
+ Easier Puddle Control
+ Optimal Feeding
Features
- Enhanced premium 5183 spool solution
- Cosmetic welds
- Excellent arc clarity
- Best feeding performance - reduced shavings
Typical Applications
- Marine fabrication and repair
- Cryogenic tanks
- Shipbuilding and other high strength structural aluminum applications
- Railcars
- Offshore industry
Shielding Gas
- 100% Argon Argon / Helium Mixtures Flow Rate: 30 - 50 CFH
Special Features
- Q2 Lot® Certificate - Certified Material Test Report showing actual wire composition
Disclaimers
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
See test result disclaimer
CONFORMANCE
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.10 | ER5183 |
ABS | AWS A5.10 | ER5183 |
BV | AWS A5.10 | ER5183 |
CCS | AWS A5.10 | ER5183 |
CWB | AWS A5.10 | ER5183 |
DB | AWS A5.10 | ER5183 |
DNV-GL | AWS A5.10 | ER5183 |
KR | AWS A5.10 | ER5183 |
LR | AWS A5.10 | ER5183 |
RINA | AWS A5.10 | ER5183 |
TUV | AWS A5.10 | ER5183 |
MECHANICAL PROPERTIES
Classification | Shielding Gas | Polarity |
Tensile Strength
MPa (ksi) |
---|---|---|---|
ER5183 Requirement | Not Specified | Not Specified | 275 (40) min. |
Typical Result, As-welded | 100% Ar | DC+ | 280-310 (41-45) |
WIRE COMPOSITION
Classification | %Al | %Be | %Cr | %Fe | %Mg | %Mn | %Si | %Ti | %Total Cu | %Zn |
---|---|---|---|---|---|---|---|---|---|---|
ER5183 Requirement | Remainder | 0.0003 max. | 0.05 - 0.25 | 0.40 max. | 4.3 - 5.2 | 0.50 - 1.0 | 0.40 max. | 0.15 max. | 0.10 max. | 0.25 max. |
Typical Result | Remainder | 0.0002 | 0.07 | 0.13 | 4.9 | 0.6 | 0.05 | 0.07 | 0.00 | 0.00 |
TYPICAL OPERATING PROCEDURES
Diameter | Shielding Gas |
Gas Flow
L/min (CFH) |
Polarity |
CTWD
mm (in.) |
Wire Feed Speed
m/min (in/min) |
Voltage
volts |
Approx. Current
amps |
---|---|---|---|---|---|---|---|
Typical Result | 100% Ar | 25 (53) | DC+ | 16 (⁵/₈) | 18 (709) | 23.3 | 180 |
Typical Result | 100% Ar | 25 (53) | DC+ | 16 (⁵/₈) | 13 (512) | 24.3 | 210 |
Typical Result | 100% Ar | 25 (53) | DC+ | 19 (³/₄) | 9 (354) | 25.1 | 280 |