Détails
Traits
- Optimized for burn-through spot welding
- Deep penetration
- Little slag interference in arc
Applications typiques
- Spot Welding
- Decking to beams
- Steel with moderate surface contaminants
Positions de soudage
- Flat/Horizontal
Gaz de protection
- Not Applicable
Disclaimers
Des informations de service
Vous pourriez également avoir besoin
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
See test result disclaimer
CONFORMANCE
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.1 | E6022 |
MECHANICAL PROPERTIES
Classification |
Transverse Tensile Strength
MPa (ksi) |
Longitudinal Face Bend |
---|---|---|
E6022 Requirement | 410 (60) min. | No opening in excess of 1/8 inch |
Typical Result, As-welded | 450-540 (65-78) | Pass |
TYPICAL OPERATING PROCEDURES
Diameter | Polarity⁽¹⁾ |
Current
Amps |
---|---|---|
1/8 in (3.2 mm) | DC- | 110-150 |
1/8 in (3.2 mm) | AC | 110-150 |
5/32 in (4.0 mm) | DC- | 150-180 |
5/32 in (4.0 mm) | AC | 150-180 |
NOTES
Note |
---|
⁽¹⁾ Preferred polarity is listed first. |