Détails
Traits
- Welding on galvanized and specially coated steels
- Sheet metal
- In-plant pipe welding
- Steel with moderate surface contaminants
Applications typiques
- Mild Steel, Cellulosic • AWS E6011
- Sheet metal
- In-plant pipe welding
- Steel with moderate surface contaminants
Positions de soudage
- All
Gaz de protection
- Not Applicable
Disclaimers
Des informations de service
Vous pourriez également avoir besoin
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
See test result disclaimer
CONFORMANCE
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.1 | E6011 |
ISO | ISO 2560-B | E4311 A |
ABS | AWS A5.1 | E6011 |
LR | LR - Chapter 11 | 3M |
MECHANICAL PROPERTIES
Classification |
Yield Strength @ 0.2% Offset
MPa (ksi) |
Tensile Strength
MPa (ksi) |
Elongation
% |
Charpy V-Notch
J (ft-lbs) @ -30°C (-20°F) |
Hardness Rockwell B |
---|---|---|---|---|---|
E6011 Requirement | 330 (48) min. | 410 (60) min. | 22 min. | 27 (20) min. | |
Typical Result, As-welded | 360-460 (53-67) | 430-560 (62-81) | 23-37 | 33-103 (24-76) | 73-89 |
DEPOSIT COMPOSITION
Classification | %C | %Cr | %Mn | %Mo | %Ni | %P | %S | %Si | %V |
---|---|---|---|---|---|---|---|---|---|
E6011 Requirement | 0.20 max. | 0.20 max. | 1.20 max. | 0.30 max. | 0.30 max. | 1.00 max. | 0.08 max. | ||
Typical Result | 0.08-0.16 | 0.01-0.05 | 0.31-0.60 | 0.02 max. | 0.04 max. | 0.004-0.013 | 0.004-0.014 | 0.09-0.30 | 0.01 max. |
TYPICAL OPERATING PROCEDURES
Diameter | Polarity⁽¹⁾ |
Current
Amps |
---|---|---|
3/32 in (2.4 mm) | AC | 50-85 |
3/32 in (2.4 mm) | DC± | 40-75 |
1/8 in (3.2 mm) | AC | 75-120 |
1/8 in (3.2 mm) | DC± | 70-110 |
5/32 in (4.0 mm) | AC | 90-160 |
5/32 in (4.0 mm) | DC± | 80-145 |
3/16 in (4.8 mm) | AC | 120-200 |
3/16 in (4.8 mm) | DC± | 110-180 |
7/32 in (5.6 mm) | AC | 150-260 |
7/32 in (5.6 mm) | DC± | 135-235 |
1/4 in (6.4 mm) | AC | 190-300 |
1/4 in (6.4 mm) | DC± | 170-270 |
NOTES
Note |
---|
⁽¹⁾ Preferred polarity is listed first. |