Hardfacing Consumables Family Group

Diameters / Packaging

Diameters
25 lb (11.3 kg) Coil
5/64 in (2.0 mm) ED035628

Lincore® TiCore

Flux-Cored Self-Shielded (FCAW-S)

LINCORE® TiCore Flux-Cored Self-Shielded Wire designed for wear plate, crusher rolls and ore chutes applications (Metal to Earth)

Détails

LINCORE® TICORE provides better wear characteristics than martensitic only deposit, low spatter and easy slag cleanup for crack resistance offers deposit limited to four layers maximum.

Traits

  • Better wear characteristics than martensitic only deposit
  • Low spatter and easy slag cleanup
  • Deposits do not check crack
  • Limited to 4 layers max

Applications typiques

  • Wear plate
  • Crusher rolls
  • Ore Chutes

Positions de soudage

  • Flat/Horizontal

Disclaimers

Warning -

Cancer and Reproductive Harm -

www.P65Warnings.ca.gov

BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page

See test result disclaimer

MECHANICAL PROPERTIES

Classification Hardness Rockwell C Mass Loss (G65)
Typical Result 52-60 0.27

DEPOSIT COMPOSITION

Classification Number of layer %C %Cr %Mn %Mo %Si %Ti %V
Typical Result 4 Layers 2.5 8.5 1.3 1.9 1.5 8.6 0.4

TYPICAL OPERATING PROCEDURES

Diameter Polarity ESO
mm (in.)
Wire Feed Speed
m/min (in/min)
Voltage
volts
Approx. Current
amps
5/64 in (2.0 mm) DC+ 38 (1 1/2) 5.1 (200) 27 260