DETAILS
LINCORE® 55-G Produces a deposit which resists metal-to-metal wear and mild abrasion to be used on carbon steel and low alloy steel offers unlimited layers with proper preheat and interpass temperatures and procedures.
Eigenschaften
- Für unlegierten und niedriglegierten Stahl
- Unbegrenzte Lagenanzahl mit entsprechender Vorwärmung und Zwischenlagentemperatur
- Schweißgut beständig gegen Metall-auf-Metall- und leichten Reib-Verschleiß
- Unlimited layers with proper preheat and interpass temperatures and procedures
Service Informationen
Ergänzende Produkte
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS-Suchseite
MECHANICAL PROPERTIES
Classification | Shielding Gas | Hardness Rockwell C |
---|---|---|
Typical Result | 98% Ar, 2% O2 | 56-59 |
Typical Result | 75% Ar, 25% CO2 | 59-61 |
DEPOSIT COMPOSITION
Classification | Product Size | Number of layer | Shielding Gas | %C | %Cr | %Mn | %Mo | %Si |
---|---|---|---|---|---|---|---|---|
Typical Result | .045" (1.1 mm) | 2 Layers | 75% Ar, 25% CO2 | 0.39 | 5.6 | 1.2 | 0.6 | 0.8 |
Typical Result | .045" (1.1 mm) | 2 Layers | 98% Ar, 2% O2 | 0.47 | 6.4 | 1.4 | 0.6 | 1.0 |
Typical Result | 1/16" (1.6 mm) | 2 Layers | 75% Ar, 25% CO2 | 0.41 | 5.3 | 1.2 | 0.6 | 0.8 |
Typical Result | 1/16" (1.6 mm) | 2 Layers | 98% Ar, 2% O2 | 0.45 | 5.5 | 1.2 | 0.6 | 1.0 |
TYPICAL OPERATING PROCEDURES
Diameter | Shielding Gas | Polarity |
ESO
mm (in.) |
Wire Feed Speed
m/min (in/min) |
Voltage
volts |
Approx. Current
amps |
Deposition Rate
kg/hr (lb/hr) |
---|---|---|---|---|---|---|---|
0.045 in (1.1 mm) | 75% Ar / 25% CO2 | DC+ | 16 (5/8) | 5.1 (200) | 27 | 165 | 2.0 (4.3) |
0.045 in (1.1 mm) | 75% Ar / 25% CO2 | DC+ | 16 (5/8) | 7.6 (300) | 29 | 225 | 3.0 (6.7) |
0.045 in (1.1 mm) | 75% Ar / 25% CO2 | DC+ | 16 (5/8) | 10.2 (400) | 31 | 290 | 4.2 (9.2) |
0.045 in (1.1 mm) | 90% Ar / 10% CO2 | DC+ | 20 (3/4) | 5.1 (200) | 25 | 145 | 2.1 (4.7) |
0.045 in (1.1 mm) | 90% Ar / 10% CO2 | DC+ | 20 (3/4) | 7.6 (300) | 28 | 195 | 3.3 (7.2) |
0.045 in (1.1 mm) | 90% Ar / 10% CO2 | DC+ | 20 (3/4) | 10.2 (400) | 30 | 245 | 4.4 (9.7) |
0.045 in (1.1 mm) | 98% Ar / 2% O2 | DC+ | 20 (3/4) | 5.1 (200) | 25 | 145 | 2.3 (5.1) |
0.045 in (1.1 mm) | 98% Ar / 2% O2 | DC+ | 20 (3/4) | 7.6 (300) | 27 | 200 | 3.4 (7.5) |
0.045 in (1.1 mm) | 98% Ar / 2% O2 | DC+ | 20 (3/4) | 8.9 (350) | 28 | 225 | 3.9 (8.7) |
0.045 in (1.1 mm) | 98% Ar / 2% O2 | DC+ | 20 (3/4) | 10.2 (400) | 29 | 250 | 4.4 (9.8) |
1/16 in (1.6 mm) | 75% Ar / 25% CO2 | DC+ | 20 (3/4) | 3.8 (150) | 28 | 260 | 2.6 (5.8) |
1/16 in (1.6 mm) | 75% Ar / 25% CO2 | DC+ | 20 (3/4) | 6.4 (250) | 30 | 340 | 4.7 (10.4) |
1/16 in (1.6 mm) | 75% Ar / 25% CO2 | DC+ | 20 (3/4) | 8.9 (350) | 32 | 420 | 6.8 (15.1) |
1/16 in (1.6 mm) | 90% Ar / 10% CO2 | DC+ | 20 (3/4) | 3.8 (150) | 25 | 230 | 2.7 (6.0) |
1/16 in (1.6 mm) | 90% Ar / 10% CO2 | DC+ | 20 (3/4) | 6.4 (250) | 27 | 315 | 4.9 (10.7) |
1/16 in (1.6 mm) | 90% Ar / 10% CO2 | DC+ | 20 (3/4) | 8.9 (350) | 29 | 400 | 7.0 (15.4) |
1/16 in (1.6 mm) | 98% Ar / 2% O2 | DC+ | 20 (3/4) | 3.8 (150) | 24 | 220 | 2.9 (6.4) |
1/16 in (1.6 mm) | 98% Ar / 2% O2 | DC+ | 20 (3/4) | 6.4 (250) | 26 | 315 | 5.0 (11.0) |
1/16 in (1.6 mm) | 98% Ar / 2% O2 | DC+ | 20 (3/4) | 8.9 (350) | 28 | 410 | 7.1 (15.7) |
NOTES
Note |
---|
Interpass temperatures between 150°C (300°F) and 200°C (400°F) do not affect the hardness of Lincore® 55 significantly. |