SuperArc MIG wire, 33 lb. Plastic spool

Durchmesser / Lieferform

Durchmesser
33 lb Spool
1,1 mm (0,045 in) ED032928

SuperArc® L-56® MIG (GMAW) Wire

MIG/MAG Schweißen (GMAW) | ED032928

KLASSIFIZIERUNGEN::
ER70S-6

SuperArc® L-56® is Lincoln Electric's premium copper coated MIG wire and an excellent choice for welding on metals with a medium to high presence of millscale.

DETAILS

Lincoln's premium copper coated MIG wire, SuperArc® L-56® is an excellent choice for welding on metals with a medium to high presence of millscale.

Eigenschaften

  • High levels of manganese and silicon deoxidizers tolerate medium to heavy mill scale surfaces
  • Excellent toe-wetting provides optimal bead appearance
  • Copper coated for long contact tip life
  • Supports short-circuiting, globular, axial spray and pulsed spray transfer
  • Available to meet Buy America. Choose a Buy America MTS product from the list of Available Types or contact a Lincoln Electric representative

Service Informationen

Ergänzende Produkte

BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS-Suchseite

CONFORMANCE

CONFORMANCES SPECIFICATION CLASSIFICATION
AWS AWS A5.18 ER70S-6
ABS ABS - Part 2 3YSA, 3YSA H5
CWB CSA W48 B-G 49A 3 C1 S6, B-G 49A 3 C1 S6 (B-G 49A 3 C G6), B-G 49A 3 Z S6
DNV-GL DNV - 2.9 III YMS H5
DB ISO 14341-A G 42 3 C1 3Si1, G 46 4 M21 3Si1
LR LR - Chapter 11 3YS H5
MIL MIL-E-23765/1D MIL-70S-6

MECHANICAL PROPERTIES

Classification Shielding Gas Polarity Yield Strength @ 0.2% Offset
MPa (ksi)
Tensile Strength
MPa (ksi)
Elongation
%
Charpy V-Notch
J (ft-lbs) @ -30°C (-20°F)
Charpy V-Notch
J (ft-lbs) @ -40°C (-40°F)
ER70S-6 Requirement 100% CO2 DC+ 400 (58) min. 480 (70) min. 22 min. 27 (20) min.
Typical Result, As-welded 100% CO2 DC+ 420 (61) 530-570 (77-82) 25 43-121 (32-89)
Typical Result, As-welded 75% Ar, 25% CO2 DC+ 430 (62) 530-600 (77-86) 23 62-182 (46-135) 42-156 (31-115)
Typical Result, As-welded 90% Ar, 10% CO2 DC+ 490 (71) 600 (87) 24 87-109 (64-80)

WIRE COMPOSITION

Classification %C %Cr %Mn %Mo %Ni %P %S %Si %V %Total Cu
ER70S-6 Requirement 0.06 - 0.15 0.15 max. 1.40 - 1.85 0.15 max. 0.15 max. 0.025 max. 0.035 max. 0.80 - 1.15 0.03 max. 0.50 max.
Typical Result 0.07-0.10 0.01-0.05 1.41-1.58 0.01 max. 0.03 max. 0.003-0.013 0.013 max. 0.80-0.98 0.005 max. 0.13-0.29

TYPICAL OPERATING PROCEDURES

Diameter Transfer Mode Shielding Gas Polarity CTWD
mm (in.)⁽¹⁾
Wire Feed Speed
m/min (in/min)
Voltage
volts
Approx. Current
amps
Melt-off Rate
kg/hr (lb/hr)
0.025 in (0.6 mm) Short Circuit Transfer 100% CO2 DC+ 9-12 (3/8-1/2) 2.5 (100) 17 35 0.4 (0.9)
0.025 in (0.6 mm) Short Circuit Transfer 100% CO2 DC+ 9-12 (3/8-1/2) 6.4 (250) 19 80 0.9 (2.0)
0.030 in (0.8 mm) Short Circuit Transfer 100% CO2 DC+ 9-12 (3/8-1/2) 1.9 (75) 17 35 0.4 (0.9)
0.030 in (0.8 mm) Short Circuit Transfer 100% CO2 DC+ 9-12 (3/8-1/2) 3.8 (150) 18 70 0.8 (1.8)
0.030 in (0.8 mm) Short Circuit Transfer 100% CO2 DC+ 9-12 (3/8-1/2) 7.6 (300) 22 130 1.6 (3.6)
0.035 in (0.9 mm) Short Circuit Transfer ⁽²⁾ 100% CO2 DC+ 9-12 (3/8-1/2) 2.5 (100) 18 80 0.7 (1.6)
0.035 in (0.9 mm) Short Circuit Transfer ⁽²⁾ 100% CO2 DC+ 9-12 (3/8-1/2) 3.8 (150) 19 120 1.1 (2.4)
0.035 in (0.9 mm) Short Circuit Transfer ⁽²⁾ 100% CO2 DC+ 9-12 (3/8-1/2) 6.4 (250) 22 175 1.8 (4.0)
0.035 in (0.9 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-19 (1/2-3/4) 9.5 (375) 23 195 2.7 (6.0)
0.035 in (0.9 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-19 (1/2-3/4) 12.7 (500) 29 230 3.6 (8.0)
0.035 in (0.9 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-19 (1/2-3/4) 15.2 (600) 30 275 4.4 (9.6)
0.045 in (1.1 mm) Short Circuit Transfer ⁽²⁾ 100% CO2 DC+ 12-19 (1/2-3/4) 3.2 (125) 19 145 1.5 (3.4)
0.045 in (1.1 mm) Short Circuit Transfer ⁽²⁾ 100% CO2 DC+ 12-19 (1/2-3/4) 3.8 (150) 20 165 1.8 (4.0)
0.045 in (1.1 mm) Short Circuit Transfer ⁽²⁾ 100% CO2 DC+ 12-19 (1/2-3/4) 5.1 (200) 21 200 2.5 (5.4)
0.045 in (1.1 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-19 (1/2-3/4) 8.9 (350) 27 285 4.2 (9.2)
0.045 in (1.1 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-19 (1/2-3/4) 12.1 (475) 30 335 5.7 (12.5)
0.045 in (1.1 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-19 (1/2-3/4) 12.7 (500) 30 340 6.0 (13.2)
0.052 in (1.3 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-19 (1/2-3/4) 7.6 (300) 30 300 4.8 (10.7)
0.052 in (1.3 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-19 (1/2-3/4) 8.1 (320) 30 320 5.2 (11.5)
0.052 in (1.3 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-19 (1/2-3/4) 12.3 (485) 32 430 7.8 (17.1)
1/16 in (1.6 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-25 (1/2-1) 5.3 (210) 27 325 4.8 (10.7)
1/16 in (1.6 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-25 (1/2-1) 6.0 (235) 28 350 5.4 (12.0)
1/16 in (1.6 mm) Spray Transfer 90% Ar / 10% CO2 DC+ 12-25 (1/2-1) 7.4 (290) 29 430 6.7 (14.8)

NOTES

Note
⁽¹⁾ CTWD (Contact Tip to Work Distance). Subtract 1/4 in (6.4 mm) to calculate Electrical Stickout