Image not found

Diameters / Packaging

Diameters
10 lb (4.5 kg) Plastic Spool
25 lb (11.3 kg) Plastic Spool
25 lb (11.3 kg) Steel Spool
500 lb (227 kg) Accu-Trak® Drum
0.045 in (1.1 mm) ED036444 ED028176 ED031475
0.052 in (1.3 mm) ED037409 ED037410
1/16 in (1.6 mm) ED028177 ED032661

Lincore® 55-G Flux-Cored (FCAW-G) Wire

Flux-Cored Gas-Shielded (FCAW-G) | ED037409

AWS:
EN/ISO : T Fe2

LINCORE® 55-G Flux-Cored Gas Shielded Wire designed for crane wheels, blower blades, bucket lips, dredge parts and tillage tools applications (Metal to Metal or Metal to Earth Abrasion)

DETAILS

LINCORE® 55-G Produces a deposit which resists metal-to-metal wear and mild abrasion to be used on carbon steel and low alloy steel offers unlimited layers with proper preheat and interpass temperatures and procedures.

Features

  • Produces a deposit which resists metal-to-metal wear and mild abrasion
  • The deposit results in an even harder material when used with the Bulk Tungsten Carbide process
  • To be used on carbon steel and low alloy steel
  • Unlimited layers with proper preheat and interpass temperatures and procedures

Disclaimers

Warning -

Cancer and Reproductive Harm -

www.P65Warnings.ca.gov

BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page

See test result disclaimer

MECHANICAL PROPERTIES

Classification Shielding Gas Hardness Rockwell C
Typical Result 98% Ar, 2% O2 56-59
Typical Result 75% Ar, 25% CO2 59-61

DEPOSIT COMPOSITION

Classification Product Size Number of layer Shielding Gas %C %Cr %Mn %Mo %Si
Typical Result .045" (1.1 mm) 2 Layers 75% Ar, 25% CO2 0.39 5.6 1.2 0.6 0.8
Typical Result .045" (1.1 mm) 2 Layers 98% Ar, 2% O2 0.47 6.4 1.4 0.6 1.0
Typical Result 1/16" (1.6 mm) 2 Layers 75% Ar, 25% CO2 0.41 5.3 1.2 0.6 0.8
Typical Result 1/16" (1.6 mm) 2 Layers 98% Ar, 2% O2 0.45 5.5 1.2 0.6 1.0

TYPICAL OPERATING PROCEDURES

Diameter Shielding Gas Polarity ESO
mm (in.)
Wire Feed Speed
m/min (in/min)
Voltage
volts
Approx. Current
amps
Deposition Rate
kg/hr (lb/hr)
0.045 in (1.1 mm) 75% Ar / 25% CO2 DC+ 16 (5/8) 5.1 (200) 27 165 2.0 (4.3)
0.045 in (1.1 mm) 75% Ar / 25% CO2 DC+ 16 (5/8) 7.6 (300) 29 225 3.0 (6.7)
0.045 in (1.1 mm) 75% Ar / 25% CO2 DC+ 16 (5/8) 10.2 (400) 31 290 4.2 (9.2)
0.045 in (1.1 mm) 90% Ar / 10% CO2 DC+ 20 (3/4) 5.1 (200) 25 145 2.1 (4.7)
0.045 in (1.1 mm) 90% Ar / 10% CO2 DC+ 20 (3/4) 7.6 (300) 28 195 3.3 (7.2)
0.045 in (1.1 mm) 90% Ar / 10% CO2 DC+ 20 (3/4) 10.2 (400) 30 245 4.4 (9.7)
0.045 in (1.1 mm) 98% Ar / 2% O2 DC+ 20 (3/4) 5.1 (200) 25 145 2.3 (5.1)
0.045 in (1.1 mm) 98% Ar / 2% O2 DC+ 20 (3/4) 7.6 (300) 27 200 3.4 (7.5)
0.045 in (1.1 mm) 98% Ar / 2% O2 DC+ 20 (3/4) 8.9 (350) 28 225 3.9 (8.7)
0.045 in (1.1 mm) 98% Ar / 2% O2 DC+ 20 (3/4) 10.2 (400) 29 250 4.4 (9.8)
1/16 in (1.6 mm) 75% Ar / 25% CO2 DC+ 20 (3/4) 3.8 (150) 28 260 2.6 (5.8)
1/16 in (1.6 mm) 75% Ar / 25% CO2 DC+ 20 (3/4) 6.4 (250) 30 340 4.7 (10.4)
1/16 in (1.6 mm) 75% Ar / 25% CO2 DC+ 20 (3/4) 8.9 (350) 32 420 6.8 (15.1)
1/16 in (1.6 mm) 90% Ar / 10% CO2 DC+ 20 (3/4) 3.8 (150) 25 230 2.7 (6.0)
1/16 in (1.6 mm) 90% Ar / 10% CO2 DC+ 20 (3/4) 6.4 (250) 27 315 4.9 (10.7)
1/16 in (1.6 mm) 90% Ar / 10% CO2 DC+ 20 (3/4) 8.9 (350) 29 400 7.0 (15.4)
1/16 in (1.6 mm) 98% Ar / 2% O2 DC+ 20 (3/4) 3.8 (150) 24 220 2.9 (6.4)
1/16 in (1.6 mm) 98% Ar / 2% O2 DC+ 20 (3/4) 6.4 (250) 26 315 5.0 (11.0)
1/16 in (1.6 mm) 98% Ar / 2% O2 DC+ 20 (3/4) 8.9 (350) 28 410 7.1 (15.7)

NOTES

Note
Interpass temperatures between 150°C (300°F) and 200°C (400°F) do not affect the hardness of Lincore® 55 significantly.