DETAILS
LINCORE® 96-S ideal for work rolls and backup rolls applications when water spray causes pitting on tool steel deposits to be used with recommended Lincoln weld® 801 and Lincoln weld® 802 standard flux for semiautomatic operations.
Features
- Caster rolls
Disclaimers
Service Information
You May Also Need
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
See test result disclaimer
MECHANICAL PROPERTIES
Flux | Classification | Hardness Rockwell C |
---|---|---|
Lincolnweld® 801® | Typical Result | 48-54 |
DEPOSIT COMPOSITION
Flux | Classification | %C | %Cr | %Mn | %Si |
---|---|---|---|---|---|
Lincolnweld® 801® | Typical Result | 0.23 | 13.0 | 1.2 | 0.4 |
TYPICAL OPERATING PROCEDURES
Diameter | Polarity |
Wire Feed Speed
m/min (in/min) |
Voltage
volts |
Approx. Current
amps |
---|---|---|---|---|
3/32 in (2.4 mm) | DC+ | 1.7 (65) | 24 | 250 |
3/32 in (2.4 mm) | DC+ | 2.5 (100) | 28 | 525 |
3/32 in (2.4 mm) | DC+ | 4.4 (175) | 31 | 450 |
1/8 in (3.2 mm) | DC+ | 1.5 (60) | 26 | 360 |
1/8 in (3.2 mm) | DC+ | 2.5 (100) | 28 | 525 |
1/8 in (3.2 mm) | DC+ | 3.6 (140) | 30 | 635 |
5/32 in (4.0 mm) | DC+ | 1.4 (55) | 27 | 450 |
5/32 in (4.0 mm) | DC+ | 2.2 (85) | 30 | 650 |
5/32 in (4.0 mm) | DC+ | 2.9 (115) | 32 | 775 |