Diameters / Packaging
Diameters |
33 lb Spool |
---|---|
0.045 in (1.1 mm) | W000403771 |
DETAILS
UltraCore® 360™ C71 has a seamless design that protects the flux core from environmental exposure helping to maintain low diffusible hydrogen and extend shelf life.
Features
- Seamless design protects the flux core from environmental exposure helping to maintain low diffusible hydrogen and extend shelf life
- Copper coating offers superior feedability and extended contact tip life
- Low spatter and fume levels for less post-weld clean up and a better work environment
- Low H4 diffusible hydrogen levels minimize the risk of hydrogen induced cracking
- Premium arc performance and bead appearance
Service Information
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
CONFORMANCE
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.20 | E71T-1C-JH4 |
AWS | AWS A5.36 | E71T1-C1A2-CS1-H4 |
MECHANICAL PROPERTIES
Classification | Shielding Gas | Polarity |
Yield Strength @ 0.2% Offset
MPa (ksi) |
Tensile Strength
MPa (ksi) |
Elongation
% |
Charpy V-Notch
J (ft-lbs) @ -40°C (-40°F) |
Charpy V-Notch
J (ft-lbs) @ -50°C (-60°F) |
---|---|---|---|---|---|---|---|
E71T-1C-JH4 Requirement | 100% CO2 | DC+ | 400 (58) min. | 480-660 (70-95) | 22 min. | 27 (20) min. | |
E71T1-C1A2-CS1-H4 Requirement | 100% CO2 | DC+ | 400 (58) min. | 480-660 (70-95) | 22 min. | ||
Typical Result, As-welded | 100% CO2 | DC+ | 520 (76) | 570-620 (83-90) | 25 | 56-139 (41-102) | 54-94 (40-69) |
DEPOSIT COMPOSITION
Classification | Shielding Gas | Polarity | %B | %C | %Mn | %P | %S | %Si |
Diffusible Hydrogen
mL/100g Weld Metal |
---|---|---|---|---|---|---|---|---|---|
E71T-1C-JH4 Requirement | 100% CO2 | DC+ | 0.12 max. | 1.75 max. | 0.03 max. | 0.03 max. | 0.90 max. | 4.0 max. | |
E71T1-C1A2-CS1-H4 Requirement | 100% CO2 | DC+ | 0.12 max. | 1.75 max. | 0.030 max. | 0.030 max. | 0.90 max. | 4 max. | |
Typical Result | 100% CO2 | DC+ | 0.0035-0.0047 | 0.08 max. | 1.19-1.36 | 0.020 max. | 0.014 max. | 0.39-0.40 | 1-2.3 |
TYPICAL OPERATING PROCEDURES
Diameter | Shielding Gas | Polarity |
CTWD
mm (in.)⁽¹⁾ |
Wire Feed Speed
m/min (in/min) |
Voltage
volts |
Approx. Current
amps |
Melt-off Rate
kg/hr (lb/hr) |
Deposition Rate
kg/hr (lb/hr) |
Efficiency
% |
---|---|---|---|---|---|---|---|---|---|
0.045 in (1.1 mm) | 100% CO2 | DC+ | 25 (1) | 6.4 (250) | 24-29 | 175 | 2.7 (5.9) | 2.4 (5.3) | 88-93 |
0.045 in (1.1 mm) | 100% CO2 | DC+ | 25 (1) | 7.6 (300) | 25-30 | 200 | 3.2 (7.0) | 2.9 (6.4) | 88-93 |
0.045 in (1.1 mm) | 100% CO2 | DC+ | 25 (1) | 8.9 (350) | 26-32 | 225 | 3.7 (8.2) | 3.4 (7.5) | 88-93 |
0.045 in (1.1 mm) | 100% CO2 | DC+ | 25 (1) | 10.2 (400) | 27-33 | 245 | 4.3 (9.4) | 3.9 (8.6) | 88-93 |
0.045 in (1.1 mm) | 100% CO2 | DC+ | 25 (1) | 11.4 (450) | 27-35 | 265 | 4.8 (10.6) | 4.4 (9.7) | 88-93 |
0.045 in (1.1 mm) | 100% CO2 | DC+ | 25 (1) | 12.7 (500) | 28-36 | 290 | 5.3 (11.7) | 4.9 (10.9) | 88-93 |
0.052 in (1.3 mm) | 100% CO2 | DC+ | 25 (1) | 5.1 (200) | 23-27 | 200 | 2.8 (6.2) | 2.6 (5.7) | 91-93 |
0.052 in (1.3 mm) | 100% CO2 | DC+ | 25 (1) | 6.4 (250) | 25-28 | 235 | 3.5 (7.7) | 3.2 (7.1) | 91-93 |
0.052 in (1.3 mm) | 100% CO2 | DC+ | 25 (1) | 8.9 (350) | 27-31 | 300 | 4.9 (10.8) | 4.5 (10.0) | 91-93 |
0.052 in (1.3 mm) | 100% CO2 | DC+ | 25 (1) | 10.8 (425) | 28-32 | 335 | 6.0 (13.1) | 5.5 (12.1) | 91-93 |
0.052 in (1.3 mm) | 100% CO2 | DC+ | 25 (1) | 12.7 (500) | 30-34 | 375 | 7.0 (15.4) | 6.5 (14.2) | 91-93 |
1/16 in (1.6 mm) | 100% CO2 | DC+ | 25 (1) | 3.8 (150) | 23-27 | 230 | 3.1 (6.7) | 2.8 (6.1) | 92-96 |
1/16 in (1.6 mm) | 100% CO2 | DC+ | 25 (1) | 5.1 (200) | 24-28 | 275 | 4.1 (9.0) | 3.8 (8.4) | 92-96 |
1/16 in (1.6 mm) | 100% CO2 | DC+ | 25 (1) | 6.4 (250) | 25-31 | 310 | 5.1 (11.3) | 4.8 (10.6) | 92-96 |
1/16 in (1.6 mm) | 100% CO2 | DC+ | 25 (1) | 7.6 (300) | 27-34 | 370 | 6.1 (13.5) | 5.8 (12.8) | 92-96 |
1/16 in (1.6 mm) | 100% CO2 | DC+ | 25 (1) | 8.9 (350) | 29-36 | 410 | 7.2 (15.8) | 6.8 (15.0) | 92-96 |
NOTES
Note |
---|
⁽¹⁾ To estimate ESO, subtract 1/4 in. (6.0 mm) from CTWD. |