Diameters / Packaging
Diameters |
55 lb Spool |
---|---|
1/8 in (3.2 mm) | ED035188 |
Détails
LINCOLNWELD® 410NiMo is used to overlay mild and low alloy steels, a preheat and inter-pass temperature of 300°F (150°C) or greater are recommended during welding. Additionally post-weld heat treatment should not exceed 1150°F (620°C) as higher temperatures may result in hardening.
Traits
- Used to overlay mild and low alloy steels
- Preheat and inter-pass temperatures of 300°F (150°C) or greater are recommended during welding
- Post-weld heat treatment should not exceed 1150°F (620° C) as higher temperatures may result in hardening
- Q2 Lot® - Certificates showing actual wire chemistry available online
Applications typiques
- Turbines
- Valve Bodies
- High Pressure Piping
- Offshore
- Power Generation
Positions de soudage
- Not applicable
Gaz de protection
- N/A
Disclaimers
Des informations de service
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
See test result disclaimer
CONFORMANCE
CONFORMANCES | SPECIFICATION | CLASSIFICATION |
---|---|---|
AWS | AWS A5.9 | ER410NiMo |
WIRE COMPOSITION
Classification | %C | %Cr | %Cu | %Mn | %Mo | %N | %Nb | %Ni | %P | %S | %Si |
---|---|---|---|---|---|---|---|---|---|---|---|
ER410NiMo Requirement | 0.06 max. | 11.0 - 12.5 | 0.75 max. | 0.6 max. | 0.4 - 0.7 | Info. Only | Info. Only | 4.0 - 5.0 | 0.03 max. | 0.03 max. | 0.5 max. |
Typical Result | 0.02-0.03 | 11.8-12.1 | 0.04-0.06 | 0.4-0.5 | 0.5-0.6 | 0.02-0.05 | 0.00 max. | 4.5-4.7 | 0.01-0.02 | 0.01 max. | 0.4 |
TYPICAL OPERATING PROCEDURES
Diameter |
Voltage
volts |
Approx. Current
amps |
Flux |
---|---|---|---|
1/8 in (3.2 mm) | 29-32 | 350-450 | Lincolnweld® P2000™ |